How and where to use guide
Deanta Windsor Black Prefinished FD30 Fire Door 1981mm x 686mm x 45mm
Installation and Fitting
Before installation, inspect the door for any damage in transit and check that your frame opening accommodates the door size plus the 15mm trim allowance on each edge. The door must be hung in a certified fire door frame assembly with appropriate hinges and seals to maintain its FD30 rating. Do not cut or modify the door beyond the stated trim allowance, as this will compromise its fire certification. Ensure the frame is square and plumb using a spirit level, and fit the door with three hinges minimum for this size. All gaps around the perimeter must be sealed with intumescent seals or fire-rated sealant to preserve the fire rating. The door should close smoothly without binding and latch securely.
- Check frame opening is within trim allowance tolerance before fitting
- Use certified fire door hinges and frame assembly
- Install intumescent seals around the entire perimeter
- Do not cut or modify beyond the 15mm per edge allowance
- Ensure door closes and latches properly without gaps
Suitable Applications and Locations
This FD30 fire door is specifically designed for internal use in kitchens, corridors, and fire-rated zones within buildings. It provides 30 minutes of fire resistance, making it suitable for compartmentalisation in domestic properties and commercial spaces where building regulations require fire safety measures. The prefinished black aesthetic makes it ideal for contemporary interiors and professional environments. Always verify local building regulations and fire safety requirements for your specific application, as FD30 doors are not suitable for external use or areas requiring higher fire ratings.
- Internal use only in kitchens, corridors, and fire zones
- Provides 30 minutes fire resistance certification
- Suitable for domestic and commercial compartmentalisation
- Not for external use or high-risk fire areas
- Verify building regulations compliance for your location
Maintenance and Care
The prefinished black surface requires minimal maintenance. Wipe down with a soft, dry cloth regularly to maintain appearance. For marks or dust, use a slightly damp cloth with mild soap solution, then dry immediately. Avoid harsh chemicals, abrasive cleaners, or excessive moisture that could damage the finish. Periodically check that intumescent seals remain intact and that the door closes properly. Do not paint over the prefinished surface without consulting the manufacturer, as this may affect the fire rating. The door is covered by a 10 Year Manufacturer's Guarantee, which covers manufacturing defects.
- Wipe with soft dry cloth for routine cleaning
- Use mild soap solution for marks; dry immediately
- Avoid harsh chemicals and abrasive cleaners
- Check seals and closure regularly for integrity
- Do not paint or modify the prefinished surface
- 10 Year Manufacturer's Guarantee covers defects
Certification and Compliance
This door is third-party certified by Q-Mark as an FD30 fire door, confirming it meets the required fire resistance standard for internal use. The FSC certification indicates the timber is sourced from responsibly managed forests. To maintain the fire rating, the door must be installed as part of a complete certified fire door assembly, including the frame, hinges, seals, and closing devices. Installation must comply with Building Regulations and any local fire safety requirements. Keep documentation of the fire door certification and installation for building control records and future reference.
- Q-Mark third-party certified FD30 fire door
- FSC certified sustainable timber sourcing
- Must be installed as complete certified assembly
- Maintain documentation for building control compliance
- Installation must meet Building Regulations requirements