Oak Regency 4 Panel Raised Moulding Unfinished Fire FD30 Door 1981mm x 762mm x 44mm (78" x 30")

Typical applications and fire safety compliance

This FD30 door is designed for use on escape routes and in fire compartmentation within buildings, meeting current building regulations for fire safety. Typical applications include internal doorways in residential properties, commercial offices, and other buildings where fire-rated separation is required by building control. The FD30 rating means the door will resist fire for 30 minutes, allowing safe evacuation. Always verify with your building control officer that this door meets the specific fire safety requirements for your installation location, as regulations vary by building type and use.

  • Suitable for escape routes and compartmentation in domestic and commercial buildings
  • FD30 rating provides 30-minute fire resistance
  • Confirm compliance with local building control before installation
  • Not suitable for external or exposed weather applications

Installation and hanging

The door is supplied pre-drilled for three standard hinges, which is the correct configuration for a door of this size and weight. Ensure the frame is square, plumb and level before hanging. The door should be hung by a competent tradesperson familiar with fire door installation, as improper hanging can compromise the fire rating. Allow adequate clearance around the frame and ensure any gaps are sealed appropriately to maintain fire performance. The 44mm thickness requires standard heavy-duty hinges rated for this door weight.

  • Pre-drilled for 3 standard hinges
  • Requires square, plumb and level frame installation
  • Hang using heavy-duty hinges suitable for 44mm doors
  • Seal gaps around frame to maintain fire rating
  • Install by experienced tradesperson to preserve FD30 certification

Finishing and on-site preparation

The door is supplied completely unfinished, so you must apply a protective finish before hanging. Sand the surface lightly with fine-grit sandpaper to prepare for staining or painting. The raised moulding detail on both faces will be more pronounced once finished. Apply your chosen stain or paint according to product instructions, ensuring even coverage across all surfaces including the panel edges and moulded details. Allow adequate drying time between coats. A quality finish will enhance durability and protect the engineered oak from moisture and wear.

  • Sand lightly with fine-grit paper before finishing
  • Apply stain or paint to all surfaces including edges and moulding
  • Allow full drying time between coats
  • Finish both faces to protect against moisture
  • Consider primer if painting to ensure even colour coverage

Maintenance and durability

The solid engineered White Oak construction provides excellent stability and longevity. The 44mm thickness contributes to both structural integrity and acoustic insulation, reducing sound transmission between rooms. Maintain the door by keeping the finished surface clean and dry. Avoid exposure to excessive moisture or direct water spray, as this can damage the finish and the wood. Periodically check hinges and hardware for tightness. The fire rating is maintained only if the door remains in good condition and is not damaged or modified after installation.

  • Engineered oak provides stability and resists warping
  • 44mm thickness offers good acoustic performance
  • Keep surface clean and protected from excessive moisture
  • Check hinges and hardware regularly for tightness
  • Do not modify or damage the door after installation as this may compromise fire rating